Skip to main content

Table 6 Envelope construction components and materials

From: Proposal for zero energy housing designs in Jordan

Component W/m2Ka

Climate zone

Materials

Thickness

Used U-Factorb

Recommended U-Factor

Mass wall above grade U-factor

1B

1 cm plaster + 15 cm brick + 14 cm insulation (Rigid board) + 7 cm concrete + 5 cm stone

42 cm

0.216

0.22

2B

1 cm plaster + 15 cm brick + 12 cm insulation (Rigid board) + 7 cm concrete + 5 cm stone

40 cm

0.26

0.3

3B

1 cm plaster + 15 cm brick + 12 cm insulation (Rigid board) + 7 cm concrete + 5 cm stone

40 cm

0.26

0.27

Roof U-factor (continuous)

1B

2 cm cement tiles + 10 cm fine aggregate and normal concrete + water proofing rolls + 16 cm Insulation (Rigid board) + 27 cm reinforced concrete + 1 cm plaster + 2 cm gypsum board

58 cm

0.202

0.21

2B

2 cm cement tiles + 10 cm fine aggregate and normal concrete + water proofing rolls + 17 cm Insulation (Rigid board) + 27 cm reinforced concrete + 1 cm plaster + 2 cm gypsum board

59 cm

0.191

0.20

3B

2 cm cement tiles + 10 cm fine aggregate and normal concrete + water proofing rolls + 17 cm Insulation (Rigid board) + 27 cm reinforced concrete + 1 cm plaster + 2 cm gypsum board

59 cm

0.191

0.19

Slab U-factor

1B, 2B, 3B

1 cm tiles + 9 cm fine aggregate and normal concrete + 10 cm reinforced concrete + 12 cm Insulation (Rigid board)

32 cm

0.243

0.27

Roof solar reflectance

 

White-scheme colours

–

0.8

0.7

  1. aContinuous insulation must be implemented to reduce thermal bridges
  2. bU-factor represents the overall thermal transmittance for an opaque assembly